OPTI CCA-TS

Back


The OPTI CCA-TS Blood Gas and Electrolyte Analyzers:
Provides fast accurate results for blood gases, acid-base balance, electrolytes, ionized calcium, glucose, BUN and lactate.
Runs samples of whole blood, plasma and serum on single-use disposable cassettes.
Uses innovative optical technology.
Requires minimal maintenance.

Innovative, economical and comprehensive
Innovative optical technology
The OPTI CCA-TS Blood Gas and Electrolyte Analyzers use OPTI Medical’s optical fluorescence technology. This unique, patented technology does not use electrodes or contact points, which eliminates the need for costly electrode maintenance.
 
Significant cost savings
The CCA-TS analyzers provide lab-quality results with zero standby cost. The single-use consumable is only used during a measurement and safely locks waste inside.
 
Wide operating temperature
The CCA-TS analyzers have a measuring chamber heated to 37°C (98.6°F). This allows for a wide operating temperature range to meet the needs of colder environments, such as the operating room.
 
Comprehensive test menu
To help meet exact testing needs, the  CCA-TS analyzers have a variety of cassette configurations available. Each cassette comes individually wrapped, in cartons of 25, reducing the potential for consumable waste.

Technology—Principles of operation
 
The CCA-TS  Blood Gas and Electrolyte Analyzers are microprocessor-based instruments that measure optical fluorescence from discreet sensors called optical electrodes (optodes). A disposable, single-use cassette contains all of the elements needed for calibration, sample measurement and waste containment. Specific calibration information from the cassette is read into the analyzer by swiping the cassette package through the bar-code reader. The cassette is then placed into the measurement chamber.
 
The analyzer warms the cassette to 37.0°C (±0.1°C)/98.6°F (±0.1°F), and it performs a calibration verification on the sensors for PCO2 and PO2 by passing a precision calibration gas mixture across the optode sensors. The pH and electrolyte channels are calibrated with precision buffer solution contained in the cassette. When calibration is verified, the analyzer aspirates the blood sample into the cassette and across the optode sensors. After equilibrating with the blood sample, fluorescence emission is then measured.
 
The CCA-TS single-use patient cassette includes these features:
Calibration of cassette before sampling—eliminates losing sample if cassette calibration fails
Long cassette shelf life—6–12 months from the date of manufacture
Easy and safe maintenance
Safe disposal—waste is locked in the cassette
Maintenance-free operation—no electrodes
Zero standby cost—no reagents required
 
OPTI® CCA-TS analyzer specifications
Calibration/Measurement
Sample Volume: 125 µL (60µL for B60 cassette)
Calibration Time: <90 seconds
Measurement Time: <120 seconds
Typical Cycle Time: <210 seconds
Operating Temperature: 10–32°C (50–90°F)
Sample Type: Whole blood, serum or plasma
Measurement Principle: Optical fluorescence, reflectance
Sample Application: Syringe, capillary or ComfortSampler®
Data Storage: 200 patient records
70 QC samples per level
105 SRC samples per level
300 user IDs and passwords